UPDATE PROCEDURE

1. Backup your SD Card by removing it from the metron and copying its contents to your computer.
2. Extract "UPDATE.BIN" from the zip file.
3. Place "UPDATE.BIN" in the root directory of your Metron sd card. Replace the file if an older one is present.
4. While Metron is powered down, place the sd card back into Metron.
5. Connect Volteras if necessary.
6. Power Metron on. The screen will read "BOOTLOADER", and an animation will play.
7. Wait until Metron fully boots to it's normal operating screen before powering down, removing SD card or playing.
8. Volteras will cycle their LEDs, showing progress in Yellow. 
       - A fully updated Voltera will have all Voltage LEDs off and a dim "select" LED.
9. Axxent will blink it's button, showing update progress. 
       - A fully updated Axxent will have a solid dim "select" LED.

----------------------------------------------------------------------------------------------------------------------------

METRON V1.72 CHANGELOG

*****************
Upgrading to 1.70 and beyond will change the save session data structure. You cannot go back to pre 1.70 versions and use saved data.
Back up your SD Card save sessions before updating.
*****************

Bug Fixes:

- Initialize Settings now clears the per channel scale settings on Voltera
- Loading Metron Sessions loads saved probability settings


Feature Additions:
- N/A

METRON V1.71 CHANGELOG -- BREAKING CHANGES

*****************
Upgrading to 1.70 and beyond will change the save session data structure. You cannot go back to pre 1.70 versions and use saved data.
Back up your SD Card save sessions before updating.
*****************

Bug Fixes:

- Clearing a memory slot will clear the same slot on Voltera
- Turning Voltera Knobs when in Random mode would lock UI to Pattern Length changes
- Fixes RollFX bug where rolls were not outputting correct patterns
- Addresses memory bugs that could cause SD card corruption


Feature Additions:
- N/A


METRON V1.70 CHANGELOG -- BREAKING CHANGES

*****************

Upgrading to 1.70 and beyond will change the save session data structure. You cannot go back to pre 1.70 versions and use saved data.

Back up your SD Card save sessions before updating.

*****************

Bug Fixes:

- Fix nudge display indicator
- Fix group following for random mode group probabilities 
- Assign input recording fixed for quantized and unquantized 
- Voltera User Scale defaults to allow all notes


Feature Additions:
- Random mode group probabilities can now be saved per variation

----------------------------------------------------------------------------------------------------------------------------

METRON V1.62 CHANGELOG   

Bug Fixes:

- Fixes loop bug that was causing crash when using assign loop

----------------------------------------------------------------------------------------------------------------------------

METRON V1.61 CHANGELOG   

Feature Additions:

- New global setting "Gate Delay" delays gate/trigger output from 0.1ms - 2ms.


----------------------------------------------------------------------------------------------------------------------------

METRON V1.60 CHANGELOG   

Bug Fixes:

- Minor Bug Fixes and Improvements.
- Record works properly for multiple gates single press.
- Smooth and Slide on Voltera work on PPQN over 4.

Feature Additions:

- Loading a blank memory slot saves a new empty session.
- New global "Reset" option, "Pre", triggers reset before step 1.

----------------------------------------------------------------------------------------------------------------------------

METRON V1.51 CHANGELOG   
-Bug: SMOOTH would sometimes add a value before the first voltage step. FIXED.
-Bug: Global Shuffle would not change past a certain value. FIXED.

----------------------------------------------------------------------------------------------------------------------------

METRON V1.5 CHANGELOG
-When viewing Voltera steps, disabled steps can now be re-enabled. The voltage on the step shows on the display.
-New SLIDE feature for Voltera. While viewing Voltera steps, press the left encoder button, press a step to enable the slide. The slide will only set if the step and the following steps are enabled.
-New SMOOTH feature that linearly interpolates between active Voltera voltage steps. Enable by pressing the left encoder button in the Voltera scale menu. 
-RANDOM feature now works on Voltera tracks. 
-Secondary RANDOM feature for Voltera that randomizes voltages while leaving enables. Hold DUPL + RANDOM and select a Voltera track.
-Duplicate a Metron track to a Voltera track.
-Voltera now clears it's session if a Metron session without an associated Voltera session is loaded.
-UI fixes.
----------------------------------------------------------------------------------------------------------------------------

METRON V1.4 CHANGELOG
-Added functionality for new Axxent expander.
-Bug: Holding a track select button and pressing clear deletes track 1. Fixed.
-Bug: Probability Layer 2 is not copied in COMPOSE ARRANGE. Fixed.
-LOOP RECORD now records Voltera information.
-Bug: Voltera LOOP playhead is off by one step. FIXED.
-RECORD FROM VARIATION now records Voltera information.
-Record mode now only follows the longest track being displayed instead of the longest in the VARIATION.
-Voltera SELECT now works in GATE/BURST/RANDOM MODE
-Bug: Voltera voltage override display would fight the playhead display in single track view. Fixed. 
-Bug: Closed Nudge ALL doesn't nudge voltera. Fixed.
-Bug: SBUS track is off by one step. Fixed.
-Pressing TRACK GROUP in MEM now returns to COMPOSE MODE.
-Bug: Certain assign input settings would cause the outputs to stay high. Fixed.
                                                     	                                                                           
----------------------------------------------------------------------------------------------------------------------------

METRON V1.31 CHANGELOG
-Voltera LOOP ENABLE was not saving when leaving the menu. Fixed
-Pressing SELECT in RANDOM/BURST/GATE freezes CURRENT STEP display. Fixed.
-Compose Scene from the button doesn't change until the next clock. Fixed.
-Single track view cannot enter steps on page 5 or above. Fixed.
-Voltera timing improvements for compatibilty with more modules. 
                                                            	                                                                           
----------------------------------------------------------------------------------------------------------------------------

METRON V1.3 CHANGELOG

-NEW SBUS USER INTERFACE
-COMPOSE SCENE MODE
-NEW END OF PATTERN MEMORY LOAD
-VOLTERA
-DUPLICATE TRACK TO ITSELF FOR PLENGTH DUP: REMOVED
-CLEAR BUTTON NOW EXITS YOU TO THE MAIN EDITOR, EVEN IN RECORD
-SINGLE TRACK VIEW NOW LATCHES RELIABLY
-GROUP PROBABILITY NOW SAVES WITH THE SESSION
-MATRIX ACTIONS ARE NOW ON RELEASE
-ERASING MEMORY SLOTS SHOWS IMMEDIATELY
-ENTER FX FILL DIRECTLY FROM MEMORY MODE
                                                            	                                                                           
----------------------------------------------------------------------------------------------------------------------------

Metron v1.2 Changelog
-"Quick Gates" now work in single track view.
-Fx Fill ROLL now exits properly when leaving the mode.
-LED Brightness Setting: Low, Med, Hi
-Settings initialization confirmation.
-Jitter reduction and minor timing improvments.
-PPQN Modes: 4PPQN, 8PPQN, 12PPQN, 24PPQN

----------------------------------------------------------------------------------------------------------------------------

Metron v1.1 Changelog
-Per track swing settings now clear on startup.
-Certain settings of microtiming could stop external clock from functioning. Fixed.
-File names were "VARXX.WMD" naming starting at 00. They are now "XX.WMD" starting at 01.
-100% gates did not work with per track swing. Fixed.
-Single track view did not always select correct track. Fixed.
-Triplet Rolls and Triplet Roll Record would sometimes skip steps. Fixed.
-Init settings was not initializing Roll patterns. Fixed.
-LOOP on odd lengths would sometimes repeat the first step. Fixed.

NOTE: This update changes the filenames that Metron looks for on the SD card. 
Any session files that you wish to access after this update will need to be renamed to the new scheme.
The "VAR" prefix should be removed from the filename, and the number should be increased by one.